Lsdyna出现“Initialization completed”后就没有了,没有error没有termination
浏览:2279  回答:1  
 
   *************************************************************** 
 
   *            ANSYS 2021 R1          LEGAL NOTICES             * 
 
   *************************************************************** 
 
   *                                                             * 
 
   * Copyright 1971-2021 ANSYS, Inc.  All rights reserved.       * 
 
   * Unauthorized use, distribution or duplication is            * 
 
   * prohibited.                                                 * 
 
   *                                                             * 
 
   * Ansys is a registered trademark of ANSYS, Inc. or its       * 
 
   * subsidiaries in the United States or other countries.       * 
 
   * See the ANSYS, Inc. online documentation or the ANSYS, Inc. * 
 
   * documentation CD or online help for the complete Legal      * 
 
   * Notice.                                                     * 
 
   *                                                             * 
 
   *************************************************************** 
 
   *                                                             * 
 
   * THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION       * 
 
   * INCLUDE TRADE SECRETS AND CONFIDENTIAL AND PROPRIETARY      * 
 
   * PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS.    * 
 
   * The software products and documentation are furnished by    * 
 
   * ANSYS, Inc. or its subsidiaries under a software license    * 
 
   * agreement that contains provisions concerning               * 
 
   * non-disclosure, copying, length and nature of use,          * 
 
   * compliance with exporting laws, warranties, disclaimers,    * 
 
   * limitations of liability, and remedies, and other           * 
 
   * provisions.  The software products and documentation may be * 
 
   * used, disclosed, transferred, or copied only in accordance  * 
 
   * with the terms and conditions of that software license      * 
 
   * agreement.                                                  * 
 
   *                                                             * 
 
   * ANSYS, Inc. is a UL registered                              * 
 
   * ISO 9001:2015 company.                                      * 
 
   *                                                             * 
 
   *************************************************************** 
 
   *                                                             * 
 
   * This product is subject to U.S. laws governing export and   * 
 
   * re-export.                                                  * 
 
   *                                                             * 
 
   * For U.S. Government users, except as specifically granted   * 
 
   * by the ANSYS, Inc. software license agreement, the use,     * 
 
   * duplication, or disclosure by the United States Government  * 
 
   * is subject to restrictions stated in the ANSYS, Inc.        * 
 
   * software license agreement and FAR 12.212 (for non-DOD      * 
 
   * licenses).                                                  * 
 
   *                                                             * 
 
   *************************************************************** 
 
        Date: 05/01/2024      Time: 10:03:52   
 
       ___________________________________________________ 
 
       |                                                 | 
 
       |  Livermore Software Technology, LLC             | 
 
       |                                                 | 
 
       |  7374 Las Positas Road                          | 
 
       |  Livermore, CA 94551                            | 
 
       |  Tel: (925) 449-2500  Fax: (925) 449-2507       | 
 
       |  www.lstc.com                                   | 
 
       |_________________________________________________| 
 
       |                                                 | 
 
       |  LS-DYNA, A Program for Nonlinear Dynamic       | 
 
       |  Analysis of Structures in Three Dimensions     | 
 
       |  Date    : 10/29/2021    Time: 15:50:06         | 
 
       |  Version : smp d R12                            | 
 
       |  Revision: R12.1-190-gadfcdf9018                | 
 
       |                                                 | 
 
       |  Features enabled in this version:              | 
 
       |    Shared Memory Parallel                       | 
 
       |    CESE CHEMISTRY EM ICFD STOCHASTIC_PARTICLES  | 
 
       |    FFTW (multi-dimensional FFTW Library)        | 
 
       |    ARPACK (nonsymmetric eigensolver library)    | 
 
       |    ANSYSLIC enabled                             | 
 
       |                                                 | 
 
       |  Licensed to:                                   | 
 
       |  Issued by  : ANSYS                             | 
 
       |                                                 | 
 
       |  Platform   : WINDOWS X64                       | 
 
       |  OS Level   : Windows 7/8/10 & Srv 2016/2019 uam| 
 
       |  Compiler   : Intel Fortran XE 2017 MSVC++ 2017 | 
 
       |  Hostname   : BJ-20230611WWVA                   | 
 
       |  Precision  : Double precision (I8R8)           | 
 
       |                                                 | 
 
       |  Unauthorized use infringes LSTC copyrights     | 
 
       |_________________________________________________| 
 
   Command line options: i=E:\Users\Administrator\Desktop\Shangbin\Structure.k  
 
                         ncpu=32  
 
                         memory=1000m 
 
   Input file: E:\Users\Administrator\Desktop\Shangbin\Structure.k                              
 
   The native file format       : 64-bit small endian 
 
   Memory size from command line:  1000000000 
 
   Memory option                : AUTO selected 
 
   allocating  memory to  1000000000 d     1966447 Initial allocation 
 
   ********  notice  ********  notice  ********  notice  ******** 
 
   *                                                            * 
 
   * This is the LS-DYNA Finite Element code.                   * 
 
   *                                                            * 
 
   * Neither LST nor the authors assume any responsibility for  * 
 
   * the validity, accuracy, or applicability of any results    * 
 
   * obtained from this system. Users must verify their own     * 
 
   * results.                                                   * 
 
   *                                                            * 
 
   * LST endeavors to make the LS-DYNA code as complete,        * 
 
   * accurate and easy to use as possible.                      * 
 
   * Suggestions and comments are welcomed.  Please report any  * 
 
   * errors encountered in either the documentation or results  * 
 
   * immediately to LST through your site focus.                * 
 
   *                                                            * 
 
   * Copyright (C) 1990-2021                                    * 
 
   * by Livermore Software Technology, LLC                      * 
 
   * All rights reserved                                        * 
 
   *                                                            * 
 
   ********  notice  ********  notice  ********  notice  ******** 
 
   Beginning of keyword reader                                   05/01/24 10:03:52 
 
   expanding   memory to   565432040 d   117909878   
 
   expanding   memory to   596843820 d   117909878   
 
   expanding   memory to   596873820 d   117909878   
 
   expanding   memory to   596933820 d   117909878   
 
   expanding   memory to   596954082 d   117909878   
 
   expanding   memory to   722613524 d   117909878   
 
   expanding   memory to   848254644 d   117909878   
 
   expanding   memory to   848276962 d   117909878   
 
   expanding   memory to   848341962 d   117909878   
 
   *** Warning 11080 (KEY+1080) 
 
       *RIGIDWALL_GEOMETRIC_FLAT ID 2 has length less than or equal to 0.0 
 
       LENL = 0.0000E+00; LENM = 0.0000E+00; 
 
   expanding   memory to   848367621 d   117909878   
 
   expanding   memory to   867695295 d   117909882   
 
   expanding   memory to   887018169 d   117909882   
 
   expanding   memory to   906351047 d   117909882   
 
   expanding   memory to   925673925 d   117909882   
 
   expanding   memory to  1138225583 d   117909882   
 
   *** Warning 70025 (OTH+25) 
 
       Memory is set 138225583 words short 
 
       increase the memory size to 1138225583 
 
   expanding   memory to  1157548463 d   117909882   
 
   *** Warning 70025 (OTH+25) 
 
       Memory is set 19322880 words short 
 
       increase the memory size to 1157548463 
 
   expanding   memory to  1176871341 d   400593405   
 
   *** Warning 70025 (OTH+25) 
 
       Memory is set 19322878 words short 
 
       increase the memory size to 1176871341 
 
   expanding   memory to  1176893641 d   400593405   
 
   *** Warning 70025 (OTH+25) 
 
       Memory is set 22300 words short 
 
       increase the memory size to 1180871341 
 
   expanding   memory to  1192598283 d   435620930   
 
   *** Warning 70025 (OTH+25) 
 
       Memory is set 11726942 words short 
 
       increase the memory size to 1192598283 
 
   expanding   memory to  1208302923 d   435620930   
 
   *** Warning 70025 (OTH+25) 
 
       Memory is set 15704640 words short 
 
       increase the memory size to 1208302923 
 
   Memory required to process keyword     :       1208m  
 
   Additional dynamic memory required     :  435620938   
 
   contracting memory to           1 d   117492236 end of keyword reader 
 
   LS-DYNA will perform a structural only analysis  
 
                           ls-dyna smp.190 d              date 10/29/2021 
 
   expanding   memory to        2773 d     1548992 material, node and element data 
 
   expanding   memory to        2851 d     1549004 mat add general damage 0 
 
   expanding   memory to        2871 d     1549004 material added airbag porosity leakage  
 
   expanding   memory to        2879 d     1549004 material properties 
 
   expanding   memory to        2885 d   240737885 element data for composite material 
 
   expanding   memory to        2899 d  4453124266 gradient of damage data 
 
   expanding   memory to        2973 d  4688693897 user control for contact interfaces 
 
   contracting memory to        2955 d  4688693897 thermal expansion 0 
 
   expanding   memory to        2957 d  4688693897 state of charge expansion 0 
 
   expanding   memory to        2959 d  4688693897 cross-sectional force definitions 0 
 
   expanding   memory to    19325837 d  4688693909 temp index array for node sorting 
 
   contracting memory to        2959 d  4708016791 just because? 
 
   expanding   memory to    15707599 d  4746662579 arbitrary element numbering input 
 
   contracting memory to        2960 d  6494535211 process element material data 
 
   expanding   memory to        4967 d  6494535209 load curve data 
 
   contracting memory to        3389 d  6494535209 user_define_loading_set 
 
   expanding   memory to        3593 d  6494535209 regularize time history data 
 
   contracting memory to        3393 d  6494535209 *DEFINE_ELEMENT_DEATH 
 
   *** Warning 21374 (STR+1374) 
 
       rigidwall ID 2 vectors n and l are not orthogonal 
 
   expanding   memory to        3598 d  6913749625 contact interfaces 
 
   expanding   memory to    38650354 d  6913749625 implicit contact 1 
 
   expanding   memory to   164287476 d  6913749625 implicit contact 2 
 
   contracting memory to        4598 d  7052692391 contact segment data 1 
 
   expanding   memory to   183610352 d  7155128093 contact segment data 3 
 
   contracting memory to        3598 d  7544221896 contact definition 
 
   expanding   memory to        3616 d  7544221897 rigid body 
 
   expanding   memory to   109752422 d  7588122053 contact friction 
 
   expanding   memory to   175601726 d  7588122053 joints 
 
   expanding   memory to   175601826 d  7675921685 rigid bodies for disp. termination 
 
   expanding   memory to   175601880 d  7675921685 save d3plot control data 
 
   expanding   memory to   175601882 d  7753213248 mat add cohesive 0 
 
   expanding   memory to   175601884 d  7753213248 sensor_control for curve 
 
   expanding   memory to   175601886 d  7753213248 flexible body 2 
 
     convergence of normal check obtained in 139 iterations 
 
     region 1 has 7317744 segments. 
 
     number of independent regions where normal vectors 
 
     are checked and if necessary reset =    1 
 
     number of renumbered segments = 0 
 
   *** Warning 30128 (INI+128) 
 
       Massless nodes 
 
       The following massless nodes were found 
 
   17902 17923 17924 17925 17926 17927 
 
   17928 17929 17930 17931 17932 17933 
 
   17934 17935 17936 17937 17938 17939 
 
   17940 173221 173222 
 
   *** Warning 30131 (INI+131) 
 
       total number of massless nodes = 21 
 
       slave surface of interface   = 1 
 
       type                         =         4 
 
       surface timestep             = 3.267E-08 
 
       controlling slave node ID    = 19496138 
 
       part ID of slave node        = 2 
 
       current minimum time step    = 3.267E-08 
 
   The LS-DYNA time step size should not exceed     3.267E-08 
 
   to avoid contact instabilities.  If the step size is 
 
   bigger then scale the penalty of the offending surface. 
 
   S t o r a g e   a l l o c a t i o n    
 
   Memory required to begin solution      :    1209M 
 
   Additional dynamically allocated memory:    7822M 
 
                                     Total:    9030M 
 
 
 
 




















 
 