地应力分析步中的参数设置
2016年7月31日 13:02*GEOSTATIC分析步几个参数(关键还是箭头所指的参数),很多人不理解,现在找到帮助文档,给大家共勉,一起学习讨论。
箭头参数设置:

箭头所指的参数:
Set this parameter equal to the tolerance for the maximum change of displacements. Abaqus/Standard will ensure that the maximum absolute value of a displacement at a node is smaller than the tolerance times the characteristic element length in the model. If this parameter is used without any value specified, the default value of 10–5 is used. If this parameter is omitted, no restrictions are imposed on the displacement values.
设置此参数等于容忍位移的最大变化。 ABAQUS/标准将确保位移的在一个节点的最大绝对值大于公差倍模型中的特征元件长度小。如果没有指定的任何值使用此参数,则使用10-5的默认值。如果省略该参数,则不作限制的位移值。
时间增量步设置:
1. Initial time increment. This value will be modified as required. If this entry is zero or is not specified, a default value that is equal to the total time period of the step is assumed.
2. Time period of the step. If this entry is zero or is not specified, a default value of 1.0 is assumed.
3. Minimum time increment allowed. If Abaqus/Standard finds it needs a smaller time increment than this value, the analysis is terminated. If this entry is zero, a default value of the smaller of the suggested initial time increment or 10–5 times the total time period is assumed.
4. Maximum time increment allowed. If this value is zero or is not specified, no upper limit is imposed.
1.初始时间增量。根据需要,此值将被修改。如果该项是零或没有指定,假定等于步骤的总时间周期的默认值。
2.时间段的步骤。如果此项为零或不指定,则假定为1.0的缺省值。
3.最小时间增量允许的。如果的Abaqus/标准发现它需要比这个值小的时间增量,所述分析被终止。如果该项是零,所建议的初始时间增量或10-5倍假定总时间的小的默认值。
4.最大时间增量允许的。如果这个值是零或没有被指定,没有上限施加。
工程师必备