热应力分析(直接法)实例——液体管路
浏览:154308
第
37
例 热应力分析(直接法)实例——液体管路
/CLEAR
/FILNAME, EXAMPLE37
/PREP7
ET, 1, 13, 4,,1
MP, KXX, 1, 70
MP, EX, 1, 2E11
MP, NUXY, 1, 0.3
MP, ALPX, 1, 1.2E-5
MP, KXX, 2, 0.02
MP, EX, 2, 2E10
MP, NUXY, 2, 0.4
MP, ALPX, 2, 1.2E-6
RECTNG, 0.14, 0.15, 0, 1
RECTNG, 0.15, 0.2, 0, 1
AGLUE, ALL
ESIZE, 0.01
MSHKEY, 1
MSHAPE, 0
AATT, 1, 1, 1
AMESH, 1
AATT, 2, 1, 1
AMESH, 3
FINISH
/SOLU
SFL, 4, CONV, 1,,70
SFL, 6, CONV, 0.5,,-40
DL, 1,,UY
DL, 3,,UY
DL, 9,,UY
DL, 10,,UY
SFL, 4, PRES, 3E5
!
TREF, 20
SOLVE
FINISH
/POST1
PLNSOL, S, EQV
FINISH