各位大神帮帮忙啊!hypermesh程序出错,不知道为啥,困扰我3天了

浏览:102157 回答:8
NOTE # 1929
Created RAM scratch area: total size 200 MB.
*** ERROR # 1000 *** in the input data:
Incorrect data in field # 3.
Detected while reading line 7091 from file
C:/Users/Administrator/Desktop/prt0001.prt.fem:
"CTETRA 8325 0 1402 2282 1324 1323"
This line was interpreted as:
7091:CTETRA, 8325, 0, 1402, 2282, 1324, 1323
Expected INT > 0, found INTEGER (0).
Syntax error(s) found in bulk data 'CTETRA' card.

*** ERROR # 1000 *** in the input data:
Incorrect data in field # 3.
Detected while reading line 7092 from file
C:/Users/Administrator/Desktop/prt0001.prt.fem:
"CTETRA 8326 0 945 3144 3129 875"
This line was interpreted as:
7092:CTETRA, 8326, 0, 945, 3144, 3129, 875
Expected INT > 0, found INTEGER (0).
Syntax error(s) found in bulk data 'CTETRA' card.

邀请回答 我来回答

全部回答

(7)
默认 最新
yiya

确认下,导入其它类似模型是否存在同样问题

2019年8月25日
评论 点赞 1
George Zhang_0236

您好,请问您这个问题解决了吗,我最近也遇到这个问题,您能否告知是如何解决的

2019年8月25日
评论 1 点赞
sixnight1
CTETRA 8325 和 8326 检查下这两个网格。估计有质量问题
2013年11月28日
评论 点赞
谢清乐
这个卡片估计他的没有。
2013年11月27日
评论 点赞
csuperfect

查看一下网格质量,参数设置等
提示说明你的'CTETRA'控制卡片有误!
2013年11月27日
评论 点赞
younshion
很有可能是三角单元的质量不行
2013年11月27日
评论 点赞
谢清乐

跟你的proe建模没关系,你的hm设置有关系。看看是否是你的控制卡片设置的不对。
2013年11月27日
评论 点赞

没解决?试试专家一对一服务

换一批
    App下载
    技术邻APP
    工程师必备
    • 项目客服
    • 培训客服
    • 平台客服

    TOP